Don’t Ignore the Signs of Misalignment

sign of misalignment

Don’t Ignore the Signs of Misalignment

Author: Stan Riddle, VibrAlign

Many companies, to their credit, use vibration analysis for diagnosing machinery problems. Whether it is done with portable data collection, cabled sensors, or wireless networks, vibration analysis is an excellent tool for diagnosing many machinery problems. But it should not be the only method used.

The coupling in the photo above was removed from a pump which had little to no signs of excessive vibration due to misalignment.

So, why didn’t vibration analysis pick it up?

While we don’t know all of the specifics regarding this machine, it is a fair assumption to say:

1. The misalignment was not severe enough to cause excessive radial or axial loading of the bearings. While the load may have been more than it should, it was not enough to cause damage –yet. Or, it could have “worn in” the coupling enough to minimize radial forces.

2. The misalignment was not severe enough to deflect the shafts, which probably would have been flagged as misalignment.

3. Any slight degrees of vibration being caused by the misalignment could have been masked by other factors, such as ambient vibration from flow, piping vibration, or vibration from nearby machines.

4. From the looks of the coupling, it was only a few start-ups from ripping out. There is very little left of either the internal or external teeth on the insert.

How would you find the misalignment?

1. Measure it, with a good alignment tool.

2. Inspect the coupling. From the wear, it probably had a great deal of orange dust inside the coupling guard.

Just as one wrench doesn’t fit every bolt, one maintenance technology can’t be used for every problem.

Read more from Stan Riddle!

Related Articles

Related Whitepapers

Arrow Powers Gas Turbine Analysis at Fern Engineering

Fern Engineering, Inc. was contracted by a major refinery to reduce the exhaust gas temperature variations of their gas turbine fleet. According to Hector Bourgeois,…

2027 DOE Efficiency Mandate & The Case for Higher Efficient Motors

The 2027 DOE motor efficiency requirements are bringing important changes to industrial motor applications. In this presentation, ABB’s Courtney Pickett and Stefanie Casimir break down…

ENKA Designs a State-of-the-Art District Heating System for Hamburg’s CHP Plant

Datacor Fathom provided the best solutions in terms of both heat transfer and pressure loss calculations.” – Kerem Algüzey, ENKA Industry: Power Generation Region: Hamburg,…

Refinery Cooling Water System Calibration Using Datacor Fathom

Hydrus Works, LLC needed to recalibrate a large refinery cooling water system containing nearly 600 pipes, 492 junctions, and 127 heat exchangers. Over 700 pressure,…