Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors

“Flushable” Wipes Clogging Issues Solved by Removing the Wet Well

Industrial Flow Solutions

“Flushable” Wipes Clogging Issues Solved by Removing the Wet Well

Overview

Submersible pump stations around the world share a common enemy, the not so “flushable” wipe. In a tradition wet well system, these wipes are separated from the pumped liquid, solidify and form clogs that result in costly maintenance service calls. Only one system solves this problem entirely: OverWatch Direct In-Line Pump System eliminates the root cause, the wet well.

Flushable Wipes Clogging Issues Solved by Removing the Wet Well

In Austin, TX, a 23-story, 320-unit high-rise residential building with a grocery store and restaurant was plagued by frequent pump clogs, 6 faults in 2 months! The culprit – “flushable” wipes! Despite multiple notifications to the building occupants, the building management team had no control over what the occupants flushed. Clogs persisted and non-budgeted pump service charges were piling up. They needed a solution that would allow the team to refocus on their main priority –providing premium living conditions for the residents.

Flushable Wipes Clogging Issues Solved by Removing the Wet Well

The team selected the OverWatch Direct In-Line Pump System to solve the repeated clogging and maintenance problems.

Solution

The Pumps of Houston service team quickly removed the antiquated submersible pumps, piping, rails, and control panel. With the equipment removed, the 60” diameter fiberglass basin was prepped for the new dry-pit system. The OverWatch arrived factory pre-tested, pre-wired, assembled, and ready to be installed. Within two and a half hours, the wet well was transformed into a dry pit and the OverWatch installation had begun 10 feet below ground.

In a safe, clean, and dry environment, the team was able to connect the suction directly to the invert and construct the discharge piping. A sump pump was used in conjunction with the system to handle any water ingress from the hatch. The valve vault was no longer needed and could be removed during future construction.

In just one day, the source of much pain and expense had been converted from a wet well into a dry, clean, and reliable pump station.

Flushable Wipes Clogging Issues Solved by Removing the Wet Well (2)

Why OverWatch? The management team needed a robust and sustainable system that also detects and annihilates potential clogs without human intervention. By removing the wet well and installing an OverWatch system, influent is lifted directly from the gravity invert, wipes and fat, oil, and grease (FOG) do not have the opportunity to separate from the pumped liquid, keeping the fibrous material in solution and ejecting it as it arrives. Since the influent is contained, it never becomes atmospheric, eliminating odors, a huge issue in the Texas heat. This game-changing technology not only eliminates the wet well, but also eliminates clogs, odors, gases, and maintenance. The building management team is saving time and money with this installation.

Related Articles

Related Whitepapers

How to Read a Pump Curve (and Why you Want to)

If you have ever worked with pumps before, be it in an installation, maintenance, or engineering capacity, chances are high you have seen a pump…

Design Optimization of Jet Fuel Pump for Aviation

Jet fuel pumps play a critical role in the safe and efficient operation of commercial aviation. The performance and reliability of these pumps directly impact…

The Cost Of Downtime In Manufacturing [Infographic]

Downtime can be the most expensive element of any manufacturing operation. Here are some important facts and tips you should know to cut down on…

AFT Fathom used to Model Central Heating Cycle of a State-of-the-art Combined Heat and Power Plant

Kerem Algüzey, design engineer at ENKA Insaat ve Sanayi A.S., used AFT Fathom to simulate the central heating cycle to inform the design of the…

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *