Generic selectors
Exact matches only
Search in title
Search in content

“Flushable” Wipes Clogging Issues Solved by Removing the Wet Well

Industrial Flow Solutions
Flushable Wipes Clogging Issues Solved by Removing the Wet Well (3)

“Flushable” Wipes Clogging Issues Solved by Removing the Wet Well

Overview

It is a story we hear time and time again; a submersible pump station requiring costly maintenance from a common villain: “flushable” wipes. But this story in Austin, Texas, finished with a happy ending, as the OverWatch Direct In-Line Pump System provided a solution to the cause of this troubling issue: the wet well.

Flushable Wipes Clogging Issues Solved by Removing the Wet Well

In the city of Austin, Texas, a 23-story, 320-unit high-rise building with a grocery store and restaurant, experienced pump station faults from clogged submersible pumps six times in two months. With each service, their service charges were excessive. The main culprit; “flushable wipes”.

Flushable Wipes Clogging Issues Solved by Removing the Wet Well

Being a residential building, they had no control over the materials that were flushed. The maintenance team had mailed multiple notifications regarding the issue, but there was no improvement. The team knew they needed a solution that was robust and hands-free. They had not budgeted for such exorbitant maintenance costs and needed to divert their focus back to providing an excellent living environment for their residents.

They selected the OverWatch Direct In-LinePump System to solve their problems.

Solution

The service team of Pumps of Houston quickly removed the old antiquated submersible pumps, piping, rails, and control panel. Once all the equipment was removed, the 60” diameter fiberglass basin was completely washed and dried in preparation for the new dry-pit system. The OverWatch arrived on site from the factory pre-tested, pre-wired, assembled, and ready to be installed. Within two and a half hours, the former wet well had been turned into a dry pit and the installation of the OverWatch had begun 10 feet below ground. In a safe, clean, and dry environment, the team was able to connect the suction directly to the invert and construct the discharge piping. A sump pump was used in conjunction with the system to handle any water ingress from the hatch. The valve vault was no longer needed and could be removed during future construction. Over the course of just one day, the source of much pain and expense had been converted to a dry, clean, and reliable pump station.

Flushable Wipes Clogging Issues Solved by Removing the Wet Well (2)

Why OverWatch? By removing the wet well and lifting influent directly from the gravity invert, FOG and wipes do not have the opportunity to separate from the pumped liquid, keeping the fibrous material in solution and ejecting it as it arrives. Because the influent is contained, there is no potential for it to become atmospheric, eliminating all concerns for odor issues in the Texas heat. Lastly, the management team needed a robust and sustainable system, one that would detect and annihilate potential clogs without human intervention. Changing the world one wet well at a time.

Related Articles

Related Whitepapers

Pump Comparison: CR & Split-Case Pumps

Introduction The GRUNDFOS CR pumps have grown into an entire line of state-of-the-art products, constructed with the finest materials. Today, continuous research, testing and innovative design…

Versatile, Reliable Pumps for Mining, Tunneling, Quarrying and Dust Suppression

Compact, Seal-less Pumps for Reliable Operation and Long Service Life With more than 40 years of experience serving the extraction industries, including major global companies,…

Solutions for Industrial Water Reuse

Water is such a fundamental necessity for life that it is often taken for granted. In modern industrial societies, the water from every tap is…

Design Optimization of a Centrifugal Compressor [Case Study]

Conceptual design of a centrifugal compressor R134a Software: CFturbo, integrated into Ansys Workbench One initial design + one manual design variation, “Design2” Mathematical optimization using…

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *

Sign up for our Newsletter!


By submitting this form, you are consenting to receive marketing emails from: Empowering Pumps & Equipment, 2205-C 7th Street, Tuscaloosa, AL, 35401, http://www.empoweringpumps.com. You can revoke your consent to receive emails at any time by using the SafeUnsubscribe® link, found at the bottom of every email. Emails are serviced by Constant Contact