Alignment of Vertical Pumps

Maintenance & Reliability
Vertical Pumps

Alignment of Vertical Pumps

Vertical pumps are used in many applications in industry. In many cases, the vertical pumps utilize a C-face flange mounting arrangement. In this arrangement, the shaft Vertical Pumpsend of the motor mounts onto an adaptor plate. It is held in place by bolts, but is positioned using a grooved joint around the periphery of the motor and plate. This joint typically seats the motor shaft centerline concentrically with the pump shaft, with only a few thousandths of an inch of error possible.

But this does not mean that the alignment quality of such machines should not be checked, especially if vibration is excessive, or if seals and bearings require frequent replacement.

Some of the more common reasons for misalignment of vertical pumps are:

  • Dirt, paint, or other contaminants on the mounting surface of the motor or plate.
  • Burrs or dents on the mounting surface of the motor or plate.
  • On rare occasions, machining errors may be present on the mounting surfaces.

When these motors are removed for maintenance, great care should be taken to not damage the mounting surfaces. The motor should be set on wooden cribbing. And before remounting the motor, the mounting surfaces should be cleaned, stoned, and checked for any other imperfections or damage. The groove on the C-face mounting should also be cleaned, to make sure no dirt or other contaminants are in the groove.

If precision alignment is required, many laser alignment tools offer options for performing vertical alignment.

Related Articles

Related Whitepapers

Arrow Powers Gas Turbine Analysis at Fern Engineering

Fern Engineering, Inc. was contracted by a major refinery to reduce the exhaust gas temperature variations of their gas turbine fleet. According to Hector Bourgeois,…

2027 DOE Efficiency Mandate & The Case for Higher Efficient Motors

The 2027 DOE motor efficiency requirements are bringing important changes to industrial motor applications. In this presentation, ABB’s Courtney Pickett and Stefanie Casimir break down…

ENKA Designs a State-of-the-Art District Heating System for Hamburg’s CHP Plant

Datacor Fathom provided the best solutions in terms of both heat transfer and pressure loss calculations.” – Kerem Algüzey, ENKA Industry: Power Generation Region: Hamburg,…

Refinery Cooling Water System Calibration Using Datacor Fathom

Hydrus Works, LLC needed to recalibrate a large refinery cooling water system containing nearly 600 pipes, 492 junctions, and 127 heat exchangers. Over 700 pressure,…