Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors

Static Head in Piping Systems (Brain Teaser #1)

Engineering & Design
Engineered Software Static Head

Static Head in Piping Systems (Brain Teaser #1)

By: PIPE-FLO

Piping System Brain Teaser #1: Static Head

PIPE-FLO decided to introduce a new thread to the “Ask an Engineer” series: Piping System Brain Teasers! We’d like to test your understanding of piping systems and challenge the way you think about them. As engineers, we constantly apply our experiences and what we’ve learned to how we view piping systems, but once in a while we’re presented with a problem that challenges our way of thinking about fluid flow in piping systems.

For example, the calculation for static head in a system may be easily done, but there are some nuances that can make you ponder what you really understand about it. From a pump’s perspective, static head is the amount of energy that it has to add to the fluid to overcome the difference in elevation head and pressure head between the source of fluid and the end users the pump is delivering the fluid to.

So let’s test your understanding of static head with the following systems. All tanks in the systems are open to atmosphere, so there is no pressure component to the static head, just static head due to elevation changes. Match these potential answers to the each system (answers can be used more than once):

A: 87 ft    B: 90 ft   C: 95 ft    D: 100 ft      E: 105 ft   F: 120 ft

System 1: _______________

System 2: _______________

System 3: _______________

System 4: _______________

System 5: _______________

Engineered SoftwareEngineered Software

Engineered Software

Engineered Software

SEE THE ANSWERS!

TRY BRAIN TEASER #2!

Related Articles

CFturbo, Inc. Launches Major Software Update

CFturbo, Inc. Launches Major Software Update

Turbomachinery software engineering company releases a new version of its user-friendly, versatile, powerful conceptual design code “CFturbo” CFturbo, Inc., an engineering…

Related Whitepapers

Arrow Powers Gas Turbine Analysis at Fern Engineering

Fern Engineering, Inc. was contracted by a major refinery to reduce the exhaust gas temperature variations of their gas turbine fleet. According to Hector Bourgeois,…

2027 DOE Efficiency Mandate & The Case for Higher Efficient Motors

The 2027 DOE motor efficiency requirements are bringing important changes to industrial motor applications. In this presentation, ABB’s Courtney Pickett and Stefanie Casimir break down…

ENKA Designs a State-of-the-Art District Heating System for Hamburg’s CHP Plant

Datacor Fathom provided the best solutions in terms of both heat transfer and pressure loss calculations.” – Kerem Algüzey, ENKA Industry: Power Generation Region: Hamburg,…

Refinery Cooling Water System Calibration Using Datacor Fathom

Hydrus Works, LLC needed to recalibrate a large refinery cooling water system containing nearly 600 pipes, 492 junctions, and 127 heat exchangers. Over 700 pressure,…