Installing Colloidal Silver

When an AEGIS ring is installed with colloidal silver on the shaft, the resistance from frame-to-shaft is often under one ohm. Without colloidal silver, it will be higher, perhaps a few ohms. But our engineers have seen installations where fully-functional AEGIS rings’ measured resistance was 30W. The ring was working; the bearings were protected. It’s just that the resistance is not that important.

Shaft voltage is what damages motor bearings when it discharges through them. So it’s the shaft voltage that you should measure to check whether the bearings are at risk.

Using an Oscilloscope for VFD-Controlled Motors

For VFD-controlled motors, you need an oscilloscope to do this. Using a scope with 100 MHz bandwidth or more lets you do two things:

First, it lets you check the maximum shaft voltage level. As a rule, shaft voltage less than 5V peak (10V peak-to-peak) is not a risk for motor bearings. You can check shaft voltage amplitude at timescales between 100 ms and 1 ms per division.AEGIS Rings Resilience Beyond Resistance Second, and more importantly, you can check for discharge at smaller timescales. The smoking gun of discharge through the bearing is voltage building up over a few ms, and then suddenly dropping back to baseline (vertical line). If you check the shaft voltage and don’t see any discharges, then the bearings are not being electrically damaged.

The takeaway is there is no harm in measuring the resistance of an AEGIS ring if you really want to, but the resistance doesn’t tell whether the bearings are protected. For that, you need to measure the shaft voltage with an oscilloscope.

Related Articles

Related Whitepapers

Arrow Powers Gas Turbine Analysis at Fern Engineering

Fern Engineering, Inc. was contracted by a major refinery to reduce the exhaust gas temperature variations of their gas turbine fleet. According to Hector Bourgeois,…

2027 DOE Efficiency Mandate & The Case for Higher Efficient Motors

The 2027 DOE motor efficiency requirements are bringing important changes to industrial motor applications. In this presentation, ABB’s Courtney Pickett and Stefanie Casimir break down…

ENKA Designs a State-of-the-Art District Heating System for Hamburg’s CHP Plant

Datacor Fathom provided the best solutions in terms of both heat transfer and pressure loss calculations.” – Kerem Algüzey, ENKA Industry: Power Generation Region: Hamburg,…

Refinery Cooling Water System Calibration Using Datacor Fathom

Hydrus Works, LLC needed to recalibrate a large refinery cooling water system containing nearly 600 pipes, 492 junctions, and 127 heat exchangers. Over 700 pressure,…