Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors

Circulators for heating systems cut energy costs by up to 20 percent

HVAC
KSB Dynamic Control

Circulators for heating systems cut energy costs by up to 20 percent

By: KSB

KSB SE & Co. KGaA, based in Frankenthal, has developed a new function, called Dynamic Control, for its circulator pumps of the Calio S and Calio type series. Dynamic Control is an intelligent program that helps cut pump input power. When compared with conventionally controlled pump sets Dynamic Control cuts power by up to 20%.

Modern circulators change their speed to match current demand. They adjust their flow rate and head, based on an algorithm, moving the operating point along a programmed control curve.

The minimum system curve describes the friction loss when all thermostatic valves are fully opened. As the minimum system curve is usually unknown, plant designers select a control curve for conventional systems that is clearly above the minimum system curve. This uses more power than necessary and can also cause disturbing noises at the radiators’ thermostatic valves.

Dynamic Control moves the operating point down from the currently selected control curve until the minimum system curve is reached. Should the latter be undercut the algorithm re-sets the pump to its original control curve, thus ensuring sufficient supply. Safe recognition of the minimum system curve by means of a flow rate signal rules out undersupply. This ensures that the building is supplied with sufficient heat.

As the implementation is purely based on software, no additional costs will be incurred by further sensors or actuators. The pump automatically gathers all required information from its internal signals. The installer no longer needs to make time-consuming settings since the pump is able to determine the system curve itself. The operator benefits from lower energy costs and less noise. Reducing energy also has a positive effect on the carbon footprint.

The new function is already integrated in the current Calio and Calio S type series and can be installed as an update in pumps of the third generation of this type.

Related Articles

AHR Expo releases 2025 Education Program

AHR Expo releases 2025 Education Program

Professionals from the field provide insight, tips and best practices on current industry trends The AHR Expo (International Air-Conditioning, Heating, Refrigerating…

Related Whitepapers

Advanced Sealing and Condition Monitoring Strategies In Water and Wastewater Plants

Introduction As a plant/maintenance manager or reliability engineer for a water or wastewater facility, you want to know about the best technologies to help your…

Downthrust Measurement in Vertical Pumps Prevents Failure: The Benefits of Measuring Axial Force in Real-Time

“Himmelstein’s Thrustmeter has proven to be accurate and repeatable, which are two of the main things that define quality in an instrument. It’s been a…

Electricity, Power, and Emissions: Using Motor Power Data to Create a Climate-Informed Maintenance Plan

Take Action Today To Make Your Pumps More Efficient Pump motor power levels and energy consumption provide valuable input about the status of and changes…

Energy Efficient Plant Receives Award: A Healthcare Facility Installation

Despite the complex structure of the Mater Dei hospital in Betim, Armstrong was able to deliver a reliable, energy efficient solution with the ipc 9511…

Comments

One response to “Circulators for heating systems cut energy costs by up to 20 percent”

  1. Amazing. This is certainly unique. Thanks for sharing.

Leave a Reply

Your email address will not be published. Required fields are marked *