Basic Piping Practices for Centrifugal Pumps

Iwaki
Iwaki Basic Piping Practices for Centrifugal Pumps

Basic Piping Practices for Centrifugal Pumps

Basic proper piping practices can lead to extended pump life with minimal maintenance.  Following these simple guidelines when installing your piping can lead to less headaches and downtime.

Be sure your suction piping is below your liquid level ensuring flooded suction conditions to the
pump at all times.

  • Baffle the interior of your supply tank to prevent swirling and to reduce the flow speed
  • Keep the supply tank free from debris that can enter the pump
  • Be sure the inlet piping to the pump is the same or a larger diameter than the pump inlet
  • Keep the inlet piping as short as possible but no shorter than 10x the pipe diameter (example a 2” pump suction should have 20” of straight pipe heading into the pump inlet)
  • Minimize the number of joints on the suction line and be sure all joints are completely sealed
  • Avoid areas where air pockets can form (attached)
  • Install a gate valve on the pump discharge to prevent overload during startup
  • Install an air vent valve on the discharge to purge any air on the discharge upon startup

Iwaki Basic Piping Practices for Centrifugal PumpsPump longevity and minimal maintenance it the goal of every operator.  Following these simple practices when designing your system will lead to extended pump life.  Iwaki America has over 65 years in the design and manufacturing of centrifugal sealless pumps.  Visit iwakiamerica.com for more information.

Related Articles

Related Whitepapers

Arrow Powers Gas Turbine Analysis at Fern Engineering

Fern Engineering, Inc. was contracted by a major refinery to reduce the exhaust gas temperature variations of their gas turbine fleet. According to Hector Bourgeois,…

2027 DOE Efficiency Mandate & The Case for Higher Efficient Motors

The 2027 DOE motor efficiency requirements are bringing important changes to industrial motor applications. In this presentation, ABB’s Courtney Pickett and Stefanie Casimir break down…

ENKA Designs a State-of-the-Art District Heating System for Hamburg’s CHP Plant

Datacor Fathom provided the best solutions in terms of both heat transfer and pressure loss calculations.” – Kerem Algüzey, ENKA Industry: Power Generation Region: Hamburg,…

Refinery Cooling Water System Calibration Using Datacor Fathom

Hydrus Works, LLC needed to recalibrate a large refinery cooling water system containing nearly 600 pipes, 492 junctions, and 127 heat exchangers. Over 700 pressure,…