- This event has passed.
Modeling Pump Transients With Reverse Flow
Refurbishing large non-return valves should reduce risk, not create it. But change the closing time on a 72-inch valve and you can aggravate reverse pump rotation, raising the risk of excessive shaft torque, valve torque, and motor overcurrent, potentially taking out every pump and forcing a multi-week plant shutdown.
That is exactly what Sasol faced during a valve refurbishment project on a petrochemical cooling water system: five pumps, 100,000 m3/h (440,000 gpm) of flow, and a narrow window between too fast and too slow.
Join Datacor (formerly Applied Flow Technology) for a live webinar hosted by Trey Walters, Principal, R&D at Datacor, and Nelius Joubert, Principal Process Engineer at Sasol. You will see how transient hydraulic modeling identified the safe operating range and protected the system from reverse rotation, overcurrent trips, and water hammer, plus practical, field-tested guidance on how to model pump transients with reverse flow in your own systems.
What You Will Learn:
- How four-quadrant pump modeling captures reverse flow and reverse rotation during pump trips
- Why valve closure timing has a narrow safe range, and what happens outside it
- How simulation validated a 6-12 second closure window using real field data
- Which transient pump model is preferred in different situations
- Best practices for modeling pump transients with reverse flow