Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors

Finding the Right Check Valve to Prevent Chatter

DFT Valves
DFT Valves

Finding the Right Check Valve to Prevent Chatter

By: DFT Inc.

A major University located in Texas was experiencing frequent failing swing type check valves due to worn hinge pins and missing internals caused by low flow. The swing check valves were installed in their boiler feed lines, condensate metering and condensate return lines. The low flow affected discharge of condensate pumps, centrifugal pumps and duplex pumps by causing the swing check valves to chatter and eventually fail. When failures like this happen, it is possible for the internal pieces to break off and travel down stream, which could damage other equipment.

The DFT® model SCV® check valves were the answer to this problem. The University installed .75”, .5”, 1”, 1.25”, 1.5”, and 2” sized SCV’s 750 CWP, NPT ends. The SCV spring-assisted design improved longevity and provided tight shut-off due to proper disc/ seat alignment.

DFT ValvesDFT® Model SCV® Check Valve
Features:
• 1/2” to 3” line size
• 750 & 3600 CWP
• FNPT or Socket Weld ends
• Stainless steel construction
• Inconel® X-750 spring
• Zelon® “O” ring body seal
• Edge-guided disc
• Spring assisted silent closing, non-slam
• Tight shutoff – lapped disc & seat
• Horizontal or vertical installation
• Simplified 5-part construction
• Easy maintenance
• Versatile

Related Articles

DFT Valve Check Valves For Severe Service

Check Valves For Severe Service

DFT® specializes in manufacturing check valves designed for a wide range of applications, including those that require handling severe service…

Related Whitepapers

Arrow Powers Gas Turbine Analysis at Fern Engineering

Fern Engineering, Inc. was contracted by a major refinery to reduce the exhaust gas temperature variations of their gas turbine fleet. According to Hector Bourgeois,…

2027 DOE Efficiency Mandate & The Case for Higher Efficient Motors

The 2027 DOE motor efficiency requirements are bringing important changes to industrial motor applications. In this presentation, ABB’s Courtney Pickett and Stefanie Casimir break down…

ENKA Designs a State-of-the-Art District Heating System for Hamburg’s CHP Plant

Datacor Fathom provided the best solutions in terms of both heat transfer and pressure loss calculations.” – Kerem Algüzey, ENKA Industry: Power Generation Region: Hamburg,…

Refinery Cooling Water System Calibration Using Datacor Fathom

Hydrus Works, LLC needed to recalibrate a large refinery cooling water system containing nearly 600 pipes, 492 junctions, and 127 heat exchangers. Over 700 pressure,…