Danfoss Drives in HVAC

Danfoss

Danfoss Drives in HVAC

Contributor: Danfoss Drives

Reduce total cost of ownership

Lifetime energy costs have a major impact on total cost of ownership. Even small reductions in energy use can provide vast cost savings over a relatively short timeframe. Seen over its lifetime, the initial cost of an AC drive only amounts to 10% of the total cost of ownership; the remaining 90% covers energy consumption, service and maintenance.

Features, such as Automatic Motor Adaptation and Automatic Energy Optimization, ensure that your drive is always perfectly adapted to the attached motor and changing loads. And, with minimal maintenance requirements, Danfoss AC drives provide a fast return on your HVAC investment and significantly reduce your total cost of ownership.
Calculate energy consumption with VLT® Energy Box

VLT® Energy Box software calculates, as accurately as possible, the cost, savings and payback time of using Danfoss AC drives in HVAC fan and pump applications. The tool allows you to compare the energy consumption of HVAC fans and pumps driven by Danfoss drives with alternative methods of flow control.

Applications

HVAC systems regulate the heating and cooling units in a building to provide the highest levels of comfort. The conditions are controlled by several applications which all use AC drives. Here are some of the main HVAC-related applications:

Heating

  • Boiler forced and induced draft fans
  • Primary hot water pumps
  • Fan coils
  • Heat recovery systems

Ventilation

  • Air handling units, rooftop units, supply and extract fans
  • Variable/constant air volume ventilation systems
  • Smoke ventilation, fire control and stairway ventilation systems
  • Car park ventilation systems
  • Kitchen ventilation systems

Cooling

  • Chilled water pumping systems
  • Primary/secondary pumps
  • Variable flow with primary pumps only
  • Fan coils
  • Heat recovery systems
  • Cooling tower fans, Condenser water pumps
  • Chiller compressor

Fresh water

  • Booster pumps
  • Single or parallel pumps

VLT® PHD 202 Preferred Harmonic Design

Related Articles

Related Whitepapers

Arrow Powers Gas Turbine Analysis at Fern Engineering

Fern Engineering, Inc. was contracted by a major refinery to reduce the exhaust gas temperature variations of their gas turbine fleet. According to Hector Bourgeois,…

2027 DOE Efficiency Mandate & The Case for Higher Efficient Motors

The 2027 DOE motor efficiency requirements are bringing important changes to industrial motor applications. In this presentation, ABB’s Courtney Pickett and Stefanie Casimir break down…

ENKA Designs a State-of-the-Art District Heating System for Hamburg’s CHP Plant

Datacor Fathom provided the best solutions in terms of both heat transfer and pressure loss calculations.” – Kerem Algüzey, ENKA Industry: Power Generation Region: Hamburg,…

Refinery Cooling Water System Calibration Using Datacor Fathom

Hydrus Works, LLC needed to recalibrate a large refinery cooling water system containing nearly 600 pipes, 492 junctions, and 127 heat exchangers. Over 700 pressure,…