Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors

City of Aberdeen Saved Big When They Installed A Vaughan Chopper Pump

Pumps & Operations
Vaughan Aberdeen Case Study

City of Aberdeen Saved Big When They Installed A Vaughan Chopper Pump

By: Vaughan

Vaughan Case Study
Aberdeen, WA WWTP Influent Pump
Case Study Date: October 2017

The Previous Equipment:
The Aberdeen WWTP main influent pumps were old and worn out “non-clog” type pumps, highly susceptible to plugging, and both electrically and hydraulically inefficient.

The Problem:

The old influent pumps needed to be unclogged a minimum of once daily. (2 mechanics for 1 hour = 2 labor-hours). The City of Aberdeen has not calculated the costs of low electrical and hydraulic efficiency.

In terms of costs saved, two man-hours per day at approximately $34/hr plus benefits; assume $50/hour including overhead costs. Annual cost: 365 days/year x 2 labor-hours/day x $50/labor-hours =$36,500/year in maintenance costs.

The Solution:

The City of Aberdeen purchased one 60 HP, 1180-RPM model PE8N10CS-133 Vaughan chopper pump in October 2012, 5 years ago as of the date of this case study, to see how this pump would work alongside the older influent pumps. The rated performance was 3,300 US GPM at 37 ft TDH.

Aberdeen Public Works Director shared: “We are happy with the performance of the Vaughan Chopper Pump. It has eliminated the need for daily unclogging of pumps, which eliminates the safety risks involved with cleaning a clogged pump, and maintenance has been reduced to standard preventative maintenance as opposed to repairs. Also, we seem to have a lot fewer rags throughout our system, and fewer rags reduce wear on downstream equipment and reduce the “clean-up time” when we take facilities down for maintenance.”

The Vaughan chopper pump is so effective at eliminating clogging problems and the associated costs compared to the older pumps that it is used as the primary influent pump and the older pumps are rarely used, left in standby mode.

The Results:

The Vaughan PE8N influent pump was installed in late 2012. The City of Aberdeen receives annual rainfall in the range of 70-100 inches per year, averaging 83 inches/year; Aberdeen’s WWTP averages daily flow of approximately 3.5 MGD with high flows slightly exceeding 16 MGD. Routine plugging problems in the influent station have been eliminated. The list price of this pump in 2012 was $29,060, and with the elimination of annual maintenance costs of $36,500/year, the payback for this pump was about 0.80 years or 9.6 months.

Related Articles

Hydro Adopt a Higher Standard

Adopt a Higher Standard

Enhancing performance and extending product lifespan doesn't necessarily require major design or operational overhauls. Often, modest adjustments to the standards…

Related Whitepapers

Specification Tips to Maximize Heat Transfer: Plate and Frame Exchangers

Choosing the right plate and frame heat exchanger for your application Heat exchangers are widely used in various industries including chemical, oil & gas, power…

Selecting Pump Upgrades and Operating Modifications for Existing Chilled Water System

Problem Natraj Arjunan, engineer at L&T Technology Services in Chennai India, was tasked with reviewing and simulating an existing chilled water system to diagnose system…

All-New Hydraulic Design of an Electrical Automotive Coolant Pump

CFturbo presentation at ISimT-24 in Munich/Germany! The paper “All-new Pump Design of an Electric Automotive Coolant Pump” describes a joint development between TENGAM Engineering and…

How to Read a Pump Curve (and Why you Want to)

If you have ever worked with pumps before, be it in an installation, maintenance, or engineering capacity, chances are high you have seen a pump…

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *