Contributor: PSG®

DOE Pump Efficiency

The upcoming DOE efficiency requirements for pumps will be disruptive to the pump industry and it is important for manufacturers and customers to become prepared. In this post, we are not covering all aspects of the regulation, but highlighting key features and providing good references for gaining a deeper understanding of the requirements.

DOE Summary

Compliance is required on January 27, 2020.

The ruling covers “Clean Water Pumps” as defined by the DOE in 10 CFR 431.462 https://www.ecfr.gov/cgi-bin/retrieveECFR?n=pt10.3.431#se10.3.431_1462

Clean water pump means a pump that is designed for use in pumping water with a maximum non-absorbent free solid content of 0.016 pounds per cubic foot, and with a maximum dissolved solid content of 3.1 pounds per cubic foot, provided that the total gas content of the water

Types of Pumps (http://www.pumps.org/DOE_Pumps.aspx):

End Suction Frame Mount (ESFM) [OH0, OH1]
End Suction Close Coupled (ESCC) [OH7]
In-line (IL) [OH3, OH4, OH5]
Radially Split Multi-stage Vertical in-line diffuser casing (RSV) [VS8]
Submersible Turbine (ST) [VS0]
Pump Performance Range (http://www.pumps.org/DOE_Pumps.aspx):

1 – 200 Hp (BEP)
Flow > 25 gpm (BEP)
Head < 459 ft (BEP)
14 to 248 °F
3600/1800 RPM

References

For a link to the complete Energy Conservation Program: Energy Conservation Standards for Pumps rule: (https://www.federalregister.gov/articles/2016/01/26/2016-00324/energy-conservation-program-energy-conservation-standards-for-pumps)
For a link to the Energy Conservation Program: Test Procedure for Pumps: (https://www.federalregister.gov/articles/2016/01/25/2016-00039/energy-conservation-program-test-procedure-for-pumps)
For FAQ published by the Hydraulic Institute: (http://pumps.org/EnergyEfficiency/DOE_Rulemaking/FAQs.aspx)

Blackmer® Extends its Line of GNX Series Pumps with New 3- and 4-Inch Models

Related Articles

Related Whitepapers

Arrow Powers Gas Turbine Analysis at Fern Engineering

Fern Engineering, Inc. was contracted by a major refinery to reduce the exhaust gas temperature variations of their gas turbine fleet. According to Hector Bourgeois,…

2027 DOE Efficiency Mandate & The Case for Higher Efficient Motors

The 2027 DOE motor efficiency requirements are bringing important changes to industrial motor applications. In this presentation, ABB’s Courtney Pickett and Stefanie Casimir break down…

ENKA Designs a State-of-the-Art District Heating System for Hamburg’s CHP Plant

Datacor Fathom provided the best solutions in terms of both heat transfer and pressure loss calculations.” – Kerem Algüzey, ENKA Industry: Power Generation Region: Hamburg,…

Refinery Cooling Water System Calibration Using Datacor Fathom

Hydrus Works, LLC needed to recalibrate a large refinery cooling water system containing nearly 600 pipes, 492 junctions, and 127 heat exchangers. Over 700 pressure,…