Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Products
Cutsforth Electrical Signature Analysis (ESA)

Electrical Signature Analysis (ESA)

Product by: Cutsforth Inc

Overview

Cutsforth’s Electrical Signature Analysis (ESA) uses voltage and current signals to identify motor faults. The ESA toolkit for InsightCM™ computes features specific to electrical data and motors beyond phasor and waveform analysis.

Failure modes

  • Rotor bar damage
  • Misalignment
  • Eccentricity
  • Mechanical looseness
  • Stator faults
  • Bearing faults
  • Power Quality Issues

Efficiency matters

ESA is cost effective. Monitor up to 9 motors on a single voltage bus with one acquisition device. Installation near Motor Control Centers (MCCs) minimizes cable lengths and installation costs.

Never miss a startup

Intelligent gating at the edge provides continuous monitoring while minimizing network bandwidth and storage requirements.

Leverage new or existing equipment

Make use of protective relay current transformers (CTs) and potential transformers (PTs) to simplify installation and necessary signal conditioning. You can also take advantage of existing infrastructure to minimize installation and sensing costs. If CTs and PTs are not present, make measurements directly.

Electrical Signature Analysis

Overview

Cutsforth’s Electrical Signature Analysis (ESA) uses voltage and current signals to identify motor faults. The ESA toolkit for InsightCM™ computes features specific to electrical data and motors beyond phasor and waveform analysis.

Failure modes

  • Rotor bar damage
  • Misalignment
  • Eccentricity
  • Mechanical looseness
  • Stator faults
  • Bearing faults
  • Power Quality Issues

Efficiency matters

ESA is cost effective. Monitor up to 9 motors on a single voltage bus with one acquisition device. Installation near Motor Control Centers (MCCs) minimizes cable lengths and installation costs.

Electrical Signature AnalysisNever miss a startup

Intelligent gating at the edge provides continuous monitoring while minimizing network bandwidth and storage requirements.

Leverage new or existing equipment

Make use of protective relay current transformers (CTs) and potential transformers (PTs) to simplify installation and necessary signal conditioning. You can also take advantage of existing infrastructure to minimize installation and sensing costs. If CTs and PTs are not present, make measurements directly.

ESA viewers in InsightCM

  • Trend
  • Waveform
  • Spectrum
  • High resolution spectrum
  • Torque waveform
  • Phasor diagram
  • Envelope (amplitude demodulation)
  • Park Clarke

Product Information Request

Privacy Policy:
Empowering Pumps & Equipment is committed to protecting and respecting your privacy, and we’ll only use your personal information to administer your account and to provide the products and services you requested from us and/or our partner. We may also send you our eNewsletter, of which you can unsubscribe and/or customize in your email preferences. By providing your information including email and clicking the button below, I agree to the Terms and Conditions and Privacy Policy, provide my electronic signature, and consent to receive the product/service requested. Consent is not a condition of any purchase. You may opt out any time.

*