Transforming Frequent Failures into Financial Savings: Resolving Ragging Challenges at Half Moon Bay’s Pump Station with DERAGGER®

Industrial Flow Solutions
IFS Transforming Frequent Failures into Financial Savings Resolving Ragging

Transforming Frequent Failures into Financial Savings: Resolving Ragging Challenges at Half Moon Bay’s Pump Station with DERAGGER®

Problem:

The Half Moon Bay, CA pump station, serving a community of 13,000 residents, runs on a 25 HP, 460V, 3-phase pump. This facility suffers from frequent ragging, a problem caused by the disposal of non-woven and fibrous materials. As a result, pumps clog approximately twice a week, requiring 45 minutes to an hour for each cleaning session. This issue not only diverts staff time away from other important tasks but also poses safety risks to employees due to exposure to untreated wastewater and potential sharps.

The ongoing ragging issue causes inefficiencies, as pumps with rags on the impeller suffer from reduced flow rates, extended run times, and elevated power consumption. This deviation from optimal performance affects the station’s overall efficiency and leads to higher energy bills. While installing chopper or grinder pumps could mitigate the ragging problem, these solutions bring their own set of challenges. They can increase maintenance costs and potentially cause downstream issues at the treatment facility, where small particles from grinding might complicate the screening process.

IFS Transforming Frequent Failures into Financial Savings Resolving Ragging Solution:

To address the persistent ragging problem, the Sewer Authority installed the DERAGGER® anti-ragging device. This system uses Real Time Pump Protection™ technology to detect and manage rag buildup before it causes significant clogs. By monitoring the power signature of the pump’s motor and adjusting the pump’s behavior, the DERAGGER® allows rags to pass through the impeller and be removed by downstream screens, preventing full obstructions.

The installation of the DERAGGER® led to a complete reduction in ragging, resulting in substantial savings. The authority calculated monthly savings of $735 in labor costs, as staff no longer needed to perform constant pump cleanings. Energy usage decreased by 19%, translating to a $500 monthly reduction in PG&E bills. Overall, these improvements projected an annual cost saving of $14,820 for the sewer authority.

The new system not only enhanced operational efficiency but it also improved staff safety and extended the lifespan of pump components by reducing wear and tear. The technology’s ability to detect early signs of equipment issues allows for timely maintenance, further contributing to the authority’s cost savings.

Related Articles

Related Whitepapers

Electricity, Power, and Emissions: Using Motor Power Data to Create a Climate-Informed Maintenance Plan

Take Action Today To Make Your Pumps More Efficient Pump motor power levels and energy consumption provide valuable input about the status of and changes…

Energy Efficient Plant Receives Award: A Healthcare Facility Installation

Despite the complex structure of the Mater Dei hospital in Betim, Armstrong was able to deliver a reliable, energy efficient solution with the ipc 9511…

Grundfos Heating Handbook: Hydronic Heating Systems

Grundfos’ NEW Hydronic Heating Handbook is now available. This comprehensive resource offers valuable insights into hydronic piping strategies, pump sizing, selection, troubleshooting tips, and more.…

Properties of Carbon Graphite

Laminar structure: The molecular structure of carbon graphite consists of layers of carbon atoms arranged in flat and parallel structures, providing high mechanical strength and…

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *