Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors

The Lannon, WI Pump Stations Could Not Handle Stones and Rocks

Crane Pumps & Systems
Crane

The Lannon, WI Pump Stations Could Not Handle Stones and Rocks

MUNICIPALITY OVERVIEW:
The Village of Lannon is part of the Menomonee Falls Sanitary Sewer System. The maintenance staff of Menomonee Falls manages over 200 miles of gravity sewers, 11 pumping stations and over 5,000 manholes. Menomonee Falls is a pass through operation with waste water from its collection system being treated in three treatment plants located in the Milwaukee Metropolitan Sewerage District, the Village of Sussex and the Village of Brookfield. Menomonee Falls has a population of 35,000 people with 1,200 residing in Lannon.

PUMP STATION DETAILS:
One of the most problematic pump stations for Lannon was the Main Street station. The station was built in the early 1990s and receives sewage from nearby industries, commercial establishments, condo complexes and residences. The Main Street station discharges into downstream stations before flowing into the Sussex waste water treatment plant. Since the Main Street station is located near a quarry and a construction site, water containing rocks and stones would frequently enter the station. The station also experiences huge inflow & infiltration during heavy rains. The existing non clog sewage ejector type pumps in the station were no match for the tough application and were failing and clogging repeatedly due to rags and stringy material.

CraneINSTALLATION:
Energenecs, a municipal distributor of Crane Pumps & Systems, worked with Menomonee Falls to install two 4” 10HP explosion proof Sithe chopper pumps in the lift station in April 2018. Since installation, the two pumps have been working without any issues, and Menomonee Falls’ maintenance staff hasn’t had to remove the pump for any maintenance or service. The Sithe chopper pump’s heat treated stainless blades have been chopping and pumping hard solids including stones and sand without any clogging or wear.

KEY TAKEAWAYS

PAIN POINTS:

  • The existing pump could not handle the tough solids including stones and rocks at the lift station causing it to fail repeatedly
    •  The existing pumps were clogging on rags and stringy solids

SOLUTION:

  • The Sithe Chopper pumps have been working without problem since installation
    •  The Sithe’s heat treated blades are chopping and pumping
    solids without any impact on the blades sharpness

Related Articles

Crane variable speed frequency drives Quick Start Guide

VFD Quick Start Guide

Using variable speed/frequency drives on wastewater pumps can be tricky, but if the drives are sized and programmed properly, they…

Related Whitepapers

Design Optimization of Jet Fuel Pump for Aviation

Jet fuel pumps play a critical role in the safe and efficient operation of commercial aviation. The performance and reliability of these pumps directly impact…

The Cost Of Downtime In Manufacturing [Infographic]

Downtime can be the most expensive element of any manufacturing operation. Here are some important facts and tips you should know to cut down on…

AFT Fathom used to Model Central Heating Cycle of a State-of-the-art Combined Heat and Power Plant

Kerem Algüzey, design engineer at ENKA Insaat ve Sanayi A.S., used AFT Fathom to simulate the central heating cycle to inform the design of the…

Driving Energy Savings a Commercial Facility Energy Upgrade Project

Upgrading to Design Envelope pumps helped GAC save energy costs of 20,000 AED in the first year. Armstrong’s Pump Manager service provides reports and notifications…

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *