Sealing Large Influent Pumps

A.W. Chesterton
AW Chesterton Sealing Large Influent Pumps

Sealing Large Influent Pumps

Rotating Equipment Sealing Solutions

Challenge

In large metropolitan areas, daily flows of wastewater can add up to hundreds of millions of gallons. Multiple high-volume pumps are required to move the wastewater entering the wastewater treatment plant. Due to the large shaft size, influent pumps are typically sealed with compression packing.

Solids from wastewater accelerate the normal sleeve wear, causing excessive wastewater leakage and equipment damage. The issue leads to significant downtime to replace bearings, shaft sleeves, and disassemble and transport these large pumps.

AW Chesterton Sealing Large Influent Pumps (1)

Solution

The wastewater treatment plant installed ten 15 1/4 (387 mm) Chesterton Large Split Seals in the influent pumps

Chesterton SpiralTrac™ F/S environmental controllers were installed in each pump to ensure that wastewater solids and other contaminants will not enter the stuffing box, enhancing both seal life and system reliability.

Chesterton Split Seals were installed without having to dismantle or move the pumps, significantly reducing the complexity and downtime required to repair and operate.

Results

The Chesterton sealing solution eliminated all operational leakage.

This success in turn, eliminated all the clean-up requirements and the safety issues that plant personnel had to tackle previously.

Enhanced Reliability

The large split seals increased the average MTBF to 9+ years of maintenance-free operation. Plant personnel can breathe easier knowing that their pumping systems are available for excessive demand requirements at significantly reduced maintenance and operating costs.

Why use Chesterton Split Seals?

  • Eliminate equipment tear down and the associated downtime
  • Easy installation
  • Leak-free technology
  • No packing or break-in requirements
  • Reduces or eliminates flush water usage
  • Proven maintenance and operating costs
  • Field repairable

Related Articles

Related Whitepapers

Arrow Powers Gas Turbine Analysis at Fern Engineering

Fern Engineering, Inc. was contracted by a major refinery to reduce the exhaust gas temperature variations of their gas turbine fleet. According to Hector Bourgeois,…

2027 DOE Efficiency Mandate & The Case for Higher Efficient Motors

The 2027 DOE motor efficiency requirements are bringing important changes to industrial motor applications. In this presentation, ABB’s Courtney Pickett and Stefanie Casimir break down…

ENKA Designs a State-of-the-Art District Heating System for Hamburg’s CHP Plant

Datacor Fathom provided the best solutions in terms of both heat transfer and pressure loss calculations.” – Kerem Algüzey, ENKA Industry: Power Generation Region: Hamburg,…

Refinery Cooling Water System Calibration Using Datacor Fathom

Hydrus Works, LLC needed to recalibrate a large refinery cooling water system containing nearly 600 pipes, 492 junctions, and 127 heat exchangers. Over 700 pressure,…