Sealing Large Influent Pumps

A.W. Chesterton
AW Chesterton Sealing Large Influent Pumps

Sealing Large Influent Pumps

Rotating Equipment Sealing Solutions

Challenge

In large metropolitan areas, daily flows of wastewater can add up to hundreds of millions of gallons. Multiple high-volume pumps are required to move the wastewater entering the wastewater treatment plant. Due to the large shaft size, influent pumps are typically sealed with compression packing.

Solids from wastewater accelerate the normal sleeve wear, causing excessive wastewater leakage and equipment damage. The issue leads to significant downtime to replace bearings, shaft sleeves, and disassemble and transport these large pumps.

AW Chesterton Sealing Large Influent Pumps (1)

Solution

The wastewater treatment plant installed ten 15 1/4 (387 mm) Chesterton Large Split Seals in the influent pumps

Chesterton SpiralTrac™ F/S environmental controllers were installed in each pump to ensure that wastewater solids and other contaminants will not enter the stuffing box, enhancing both seal life and system reliability.

Chesterton Split Seals were installed without having to dismantle or move the pumps, significantly reducing the complexity and downtime required to repair and operate.

Results

The Chesterton sealing solution eliminated all operational leakage.

This success in turn, eliminated all the clean-up requirements and the safety issues that plant personnel had to tackle previously.

Enhanced Reliability

The large split seals increased the average MTBF to 9+ years of maintenance-free operation. Plant personnel can breathe easier knowing that their pumping systems are available for excessive demand requirements at significantly reduced maintenance and operating costs.

Why use Chesterton Split Seals?

  • Eliminate equipment tear down and the associated downtime
  • Easy installation
  • Leak-free technology
  • No packing or break-in requirements
  • Reduces or eliminates flush water usage
  • Proven maintenance and operating costs
  • Field repairable

Related Articles

Related Whitepapers

How to Read a Pump Curve (and Why you Want to)

If you have ever worked with pumps before, be it in an installation, maintenance, or engineering capacity, chances are high you have seen a pump…

Design Optimization of Jet Fuel Pump for Aviation

Jet fuel pumps play a critical role in the safe and efficient operation of commercial aviation. The performance and reliability of these pumps directly impact…

The Cost Of Downtime In Manufacturing [Infographic]

Downtime can be the most expensive element of any manufacturing operation. Here are some important facts and tips you should know to cut down on…

AFT Fathom used to Model Central Heating Cycle of a State-of-the-art Combined Heat and Power Plant

Kerem Algüzey, design engineer at ENKA Insaat ve Sanayi A.S., used AFT Fathom to simulate the central heating cycle to inform the design of the…

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *